DIAGNOSTIC ACCURACY OF URINARY ALBUMIN CREATININE RATIO IN DETECTION OF DIABETIC NEPHROPATHY BY COMPARING WITH 24 HOURS URINARY ALBUMIN
Abstract
Objective: To determine the diagnostic accuracy of urinary albumin creatinine ratio (ACR) in detection of diabetic nephropathy by comparing with the 24 hour urinary albumin excretion (UAE).
Study Design: Â Diagnostic accuracy study.
Place and duration of study: Armed Forces Institute of Pathology, Rawalpindi, from June 2012 to December 2012.
Patients and Methods: One hundred and one subjects were selected by non-probability consecutive sampling. Subjects of either gender, aged 18-80 years were included, while known patients of hypertensive nephropathy, glomerular diseases, acute nephritis, nephritic syndrome, connective tissue diseases, toxic nephropathy, obstructive uropathy, pregnancy were excluded from the study. Urinary albumin was analyzed by means of Albumin Tina-quant Roche/Hitachi reagent kit, which utilizes a immunoturbidimeteric technology. Urinary creatinine was measured by the Jaffé assay using Beckman UniCel® DxC 600 Synchron® Clinical System. Albumin/creatinine ratio was calculated by dividing the urinary albumin concentration by the urine creatinine concentration. Urinary albumin in 24 hour was calculated by multiplying urinary albumin in 24 hour urine sample with urinary volume. Albumin creatinine ratio was compared with 24 hour urinary albumin excretion considering it as gold standard for albuminuria. ACR in spot urine was correlated with 24-h UAE with regard to Pearson correlation coefficient.Results:   Out of 101 subjects, 63(62.3%) were females and 38 (37.6%) were males. The mean age of patients were 51±15 years. Majority of patients were of 41 to 60 years of ages. Descriptive statistics median (range) for quantitative variable like 24 hours urinary albumin and spot urine albumin to creatinine ratio in males were 30.4 (2-449) and 2.8 (0.22-44.3) and in females were 38 (4.2-480) and 3.4 (0.22-44.3) respectively. Best discriminator for microalbuminuria was 3.2 mg/mmol (sensitivity of 85.2 % and specificity of 95.7 %) for both genders. For females 3.1 mg/mmol (sensitivity of 85.7 % and specificity of 92.9) and for males 2.7 mg/mmol (sensitivity of 94.7 % and specificity of 89.5 %). ACR positively correlated with 24 hour UAE (r = 0.9045) with P value of < 0.01.
Conclusion: ACR in spot urine sample can replace 24 hour urinary albumin for early detection of diabetic nephropathy.
 Key words: Microalbuminuria, 24 hours urinary albumin, Albumin to creatinine ratio, Diabetic nephropathy
Â
Downloads
Published
How to Cite
Issue
Section
License
Copyright (c) 2016 Sobia Irum, Dilshad Ahmed Khan, Aamir Ijaz, Aisha Siddiqi, Farooq Ahmad Khan

This work is licensed under a Creative Commons Attribution-NonCommercial 4.0 International License.
Readers may “Share-copy and redistribute the material in any medium or format” and “Adapt-remix, transform, and build upon the material”. The readers must give appropriate credit to the source of the material and indicate if changes were made to the material. Readers may not use the material for commercial purpose. The readers may not apply legal terms or technological measures that legally restrict others from doing anything the license permits.
