Objective: This comparative study aims to evaluate the diagnostic performance of the high-sensitive cardiac Troponin T (hs-cTnT) assay in comparison with the previous generation cardiac Troponin I (cTnI).
Material and Methods: The study was conducted at Indus Hospital and Health Network's campuses between March and May 2023. Data sourced from electronic medical record system included individuals presenting to the Emergency Department (ED) with suspected Acute Myocardial Infarction (AMI). Both 4th and 5th-generation troponin assays were performed simultaneously for all participants. Statistical analyses were employed to assess the performance of each troponin assay.
Results: Out of 354 patients, 205 were diagnosed with AMI. The use of the 5th-generation troponin assay resulted in a 37.9% increase in AMI diagnoses compared to the 4th-generation assay. Performance characteristics indicated that hs-Trop T exhibited significantly higher sensitivity at 99.02% than Trop I at 33.33%. Whereas, the specificity was similar for both the assays.
Conclusion: This study highlights that the 5th generation assay, not only revealed a notable increase in AMI diagnoses compared to its predecessor but also underscored the extent of difference in sensitivity between both assays. This discovery carries broader implications for refining diagnostic strategies in the realm of AMI, emphasizing the need for continued exploration and validation in clinical contexts.
Keywords: Myocardial infarction, Troponin assay, High sensitive troponin, Diagnostic performance study, Acute coronary syndrome
References
Ola O, Akula A, De Michieli L, Dworak M, Crockford E, Lobo R, et al. Clinical impact of high-sensitivity cardiac troponin T implementation in the community. J Am Coll Cardiol. 2021; 77: 3160-70. DOI: https://doi.org/10.1016/j.jacc.2021.04.050
Xu RY, Zhu XF, Yang Y, Ye P. High-sensitive cardiac troponin T. J Geriatr Cardiol 2013; 10:102-9. DOI: https://doi.org/10.3969/j.issn.1671-5411.2013.01.015
Andrew RC, Nicholas LM. High-sensitivity cardiac troponin and the early rule out of myocardial infarction: time for action. Heart. 2020; 106 (13): 955-7. DOI: https://doi.org/10.1136/heartjnl-2020-316811
Pickering JW, Than MP, Cullen L, Aldous S, Ter Avest E, Body R, et al. Rapid rule-out of acute myocardial infarction with a single high-sensitivity cardiac troponin T measurement below the limit of detection: A collaborative meta-analysis. Ann Intern Med 2017; 166: 715-24. DOI: https://doi.org/10.7326/m16-2562
Bularga A, Lee KK, Stewart S, Ferry AV, Chapman AR, Marshall L, et al. High-sensitivity troponin and the application of risk stratification thresholds in patients with suspected acute coronary syndrome. Circulation. 2019; 140:1557-68. DOI:https://doi.org/10.1161/circulationaha.119.042866
Vasile VC, Jaffe AS. High-sensitivity cardiac troponin in the evaluation of possible AMI. American College of Cardiology. 2018. Available from: https://www.acc.org/Latest-in-Cardiology/Articles/2018/07/16/09/17/High-Sensitivity-Cardiac-Troponin-in-the-Evaluation-of-Possible-AMI
Reichlin T, Twerenbold R, Reiter M, Steuer S, Bassetti S, Balmelli C, et al. Introduction of high-sensitivity troponin assays: Impact on myocardial infarction incidence and prognosis. Am J Med 2012; 125: 1205-13. DOI: https://doi.org/10.1016/j.amjmed.2012.07.015
Raber I, McCarthy Cian P, Januzzi James L. A test in context: Interpretation of high-sensitivity cardiac troponin assays in different clinical settings. J Am Coll Cardiol. 2021; 77: 1357-67. DOI:https://doi.org/10.1016/j.jacc.2021.01.011
Thygesen K, Alpert JS, Jaffe AS, Chaitman BR, Bax JJ, Morrow DA, et al. Fourth universal definition of myocardial infarction. J Am Coll Cardiol. 2018; 72:2231-64. DOI:https://doi.org/10.1161/CIR.0000000000000617
Neumann JT, Twerenbold R, Ojeda F, Sörensen NA, Chapman AR, Shah ASV, et al. Application of high-sensitivity troponin in suspected myocardial infarction. New Eng J Med. 2019; 380: 2529-40. DOI: https://doi.org/10.1056/nejmoa1803377
Singer AJ, Heslin S, Skopicki H, On C, Senzel LB, Tharakan M, et al. Introduction of a high sensitivity troponin reduces ED length of stay. Am J Emerg Med. 2024; 76: 82-86. DOI: https://doi.org/10.1016/j.ajem.2023.11.028
Domienik-Karłowicz J, Kupczyńska K, Michalski B, Kapłon-Cieślicka A, Darocha S, Dobrowolski P, et al. Fourth universal definition of myocardial infarction. Selected messages from the European Society of Cardiology document and lessons learned from the new guidelines on ST-segment elevation myocardial infarction and non-ST-segment elevation-acute coronary syndrome. Cardiol J. 2021; 28: 195-201. DOI: https://doi.org/10.5603/cj.a2021.0036
DeVon HA, Mirzaei S, Zègre-Hemsey J. Typical and atypical symptoms of acute coronary syndrome: Time to retire the terms? J Am Heart Assoc. 2020; 9: e015539. DOI: https://doi.org/10.1161/jaha.119.015539
Thygesen K, Mair J, Giannitsis E, Mueller C, Lindahl B, Blankenberg S, et al. How to use high-sensitivity cardiac troponins in acute cardiac care. Eur Heart J. 2012; 33: 2252-7. DOI: https://doi.org/10.1093/eurheartj/ehs154
Twerenbold R, Boeddinghaus J, Nestelberger T, Wildi K, Rubini Gimenez M, Badertscher P, et al. Clinical use of high-sensitivity cardiac troponin in patients with suspected myocardial infarction. J Am Coll Cardiol. 2017; 70: 996-1012. DOI: https://doi.org/10.1016/j.jacc.2017.07.718
Collinson P. Update on global conversion to high sensitivity cardiac troponin assays. J Lab Precis Med. 2023; 8: 15. DOI: https://dx.doi.org/10.21037/j
Işıksaçan N, Bıyık İ, Ertürk M, Koşer M, Karakurt H, Özalp B, et al. Comparison of high sensitive and conventional troponin assays in diagnosis of acute myocardial infarction. Turk J Biochem. 2017; 42 (1): 77-85. DOI: https://doi.org/10.1515/tjb-2016-0270
Al-Saleh A, Alazzoni A, Al Shalash S, Ye C, Mbuagbaw L, Thabane L, et al. Performance of the high-sensitivity troponin assay in diagnosing acute myocardial infarction: systematic review and meta-analysis. CMAJ Open. 2014; 2: E199-207. DOI: https://doi.org/10.9778/cmajo.20130074
Lazar DR, Lazar FL, Homorodean C, Cainap C, Focsan M, Cainap S, et al. High-sensitivity troponin: A review on characteristics, assessment, and clinical implications. Dis Markers 2022; 2022: 9713326. DOI: https://doi.org/10.1155/2022/9713326
Christ M, Popp S, Pohlmann H, Poravas M, Umarov D, Bach R, et al. Implementation of high sensitivity cardiac troponin T measurement in the emergency department. Am J Med. 2010; 123: 1134-42. DOI: https://doi.org/10.1016/j.amjmed.2010.07.015
Apple FS, Smith SW, Greenslade JH, Sandoval Y, Parsonage W, Ranasinghe I, et al. Single high-sensitivity point-of-care whole-blood cardiac troponin I measurement to rule out acute myocardial infarction at low risk. Circulation 2022; 146: 1918-29. DOI:https://doi.org/10.1161/circulationaha.122.061148
Reichlin T, Schindler C, Drexler B, Twerenbold R, Reiter M, Zellweger C, et al. One-hour rule-out and rule-in of acute myocardial infarction using high-sensitivity cardiac troponin T. Arch Intern Med 2012; 172: 1211-8.
DOI:https://doi.org/10.1001/archinternmed.2012.3698
Wildi K, Nelles B, Twerenbold R, Rubini Giménez M, Reichlin T, Singeisen H, et al. Safety and efficacy of the 0 h/3 h protocol for rapid rule out of myocardial infarction. Am Heart J. 2016; 181:16-25. DOI: https://doi.org/10.1016/j.ahj.2016.07.013
Park KC, Gaze DC, Collinson PO, Marber MS. Cardiac troponins: from myocardial infarction to chronic disease. Cardiovasc Res. 2017; 113: 1708-18. DOI: https://doi.org/10.1093/cvr/cvx183
Downloads
Published
How to Cite
Issue
Section
License
Copyright (c) 2025 Dr. Mahmooda Altaf, Dr. Zoha Rasool, Dr. Muhammad Zubair, Dr. Nayab Hyder, Dr. Kainat Younas, Dr. Muhammad Baran Ellahi

This work is licensed under a Creative Commons Attribution-NonCommercial 4.0 International License.
Readers may “Share-copy and redistribute the material in any medium or format” and “Adapt-remix, transform, and build upon the material”. The readers must give appropriate credit to the source of the material and indicate if changes were made to the material. Readers may not use the material for commercial purpose. The readers may not apply legal terms or technological measures that legally restrict others from doing anything the license permits.